Control Panel Cooling unit Non-freon-gas Filter-less & Energy saving Side-mounting ENC-GR1000L-Pro ENC Series Non-freon-gas Filter-less & Energy saving Cooling capacity(W) 1000 Rated Voltage(V) Single-phase AC200~240 Mounting type Side-mounting External dimensions(mm) H730×W350×D260 Weight(kg) Approx. 26 Specifications (50/60Hz) Mounting type Side-mounting Cooling capacity(W) 1000 Setting Temperature Range(℃) 25~45 Use Area Temperature(℃) 20~55 Use Area Humidity(%RH) 10~85 (No condensation) External dimensions(mm) H730×W350×D260 Weight(kg) Approx. 26 Coating Color Equivalent color of light beige 5Y 7/1 Rated Voltage(V) Single-phase AC200~240 Consumption Current: Rated(A) 3.7 Consumption wattage: Rated(W) 600 Recommended breaker capacity (A) 10 Vibration Resistance JIS Z0200 Level1 Dust prevention / dust proof protection class Single-phase AC200~240 Refrigerant / Fill ration(g) R1234yf 320g Noise (dB (A)) Approx. 71 External Output Rated voltage normally open : 250 VAC 2A resistive load Display Internal temperature/Error/RUN Cooling Capacity : Rated capacity value when external temperature is 35°C and humidity is 40%RH , internal temperature is 35°C and humidity is 40%RH, power source & voltage : 200V. (Test method: JIS B 8615-1 Indoor air enthalpy test method) Use area temperature / humidity : Use area temperature / humi dity is not meant to satisfy all conditions in temperature and humidity. Dust prevention / dust proof protection class : Excluding dra in pipe section Reading an instruction manual well certainly before use and p lease use it right. External dimensions Diagram of Panel Cutout Capacity characteristic chart *Contact our sales representative if you are using the control panel cooler in an environment close to the permissible ambient temperature upper limit. [Caution] Please use it properly Read the manual before using Delivery of the items will be passed on the car. (Domestic location specified, except islands) will be (additional cost) Charter flights handled separately by the number, type . Overseas at the time of delivery, we recommend packing for overseas separately. Please check through the cooler between the FA and the power (circuit breakers) to the appropriate specification of the FA breaker cooler. Cause of failure and be used at the rated power supply out of range. Please use the service and maintenance on a regular basis. Failure to maintain regular maintenance, you may be a factor in product performance degradation trouble. When the outside temperature is low in winter, please do not let the FA cooler continuous operation. When disposing of this product, you should comply with various laws and regulations, please go to the appropriate.
日本Apiste阿匹斯特电气柜空调ENC-G1120L/ENC-GR1000L-Pro
相关内容
联系我们
-
咨询热线
18866622123
-
邮箱地址
sinfag@126.com -
微信号
ahyhk8
-
工作时间
周一至周五: 9:00-18:00
周六: 9:00-12:00