日本CCS电源PD3-5024-4-SI(A) 日本CCS电源PD3-5024-4-SI(A) Standard Product This Digital Control Unit can be used for LED Light Units with an input voltage of 24 V within a total power consumption of 46 W. Connection with the HLV3/HLV2-series Spot Lights is also available. This Control Unit operates on a 100 to 240 VAC input and measures 197 x 82.6 x 120 mm (width x depth x height). External control through EIA-485 communications. Add to Watch List Product Details Dimensions (mm) Options Cables Downloads Product Details Dimensions W 197 mm x D 82.6 mm x H 120 mm Applicable Light Unit (output ratings) Light Units with 24 VDC input, HLV3/HLV2 series (Spot Light) Total for 4 channels: 46 W Number of channels 4 channels Lighting method Constant/Strobe lighting Drive method 24V LIGHT connectors: Constant-voltage system, HLV LIGHT connectors: Constant-current system Intensity control method 24V LIGHT connectors: PWM control and lighting time control, HLV LIGHT connectors: Variable-current control PWM frequency 125kHz Input voltage 100 to 240 VAC (+10% -15%) Frequency 50/60 Hz Power consumption 70 VA Output voltage 24VDC Output current Total for 4 channels: 1.91 A Inrush current 15 A (at 100 VAC), 30 A (at 200 VAC) from a cold start Intensity control Manual: 256-step using the front setting switch External: Command input via EIA-485 communication Error detection display Digital display on the front-panel; OCP: Overcurrent error, EFN: Fan Stop Error, and EID: ID error (HLV3/HLV2-series Spot Lights only) Error detection output Command sent when overcurrent output is detected. Over current protection Operates at 107% of rated output current or higher. Reset by pressing operation setting switch for at least 1 second or by cycling the power supply. *Do not intentionally short-circuit the positive and negative output terminals. Output connector SMP-03V-BC x 8 External control connector Trigger input: MIL connector (MIL-C-83503 compliant), 10 pins For setting the light intensity/mode: e-CON connector, 3 pins Conformed standards CE, UKCA、RoHS Operating temperature and humidity Temperature: 0 to 40°C, Humidity: 20 to 85%RH (no condensation) Storage temperature and humidity Temperature: -20 to 60°C, Humidity: 20 to 85%RH (no condensation) Cooling method Forced cooling Weight 1,200 g Material Aluminium, ABS Accessories 2m long 3-pin power cord with ground terminal x1 Base Brackets x1 set Instruction Guide x1 Program [Sample Program] Sample programs are available. See the Options tab.
日本CCS电源PD3-5024-4-SI(A)
相关内容
联系我们
-
咨询热线
18866622123
-
邮箱地址
sinfag@126.com -
微信号
ahyhk8
-
工作时间
周一至周五: 9:00-18:00
周六: 9:00-12:00